Specifications – 2CDU
Standard
Optional
Size
Suction
2CDU70 – 1
1
/
4
'' NPT Thread
2CDU120 – 1
1
/
4
'' NPT Thread
2CDU200 – 1
1
/
2
'' NPT Thread
Discharge
1'' NPT Thread
Range of HP
2 HP to 5 HP
Range of Performance
Capacity
5.5 to 66 GPM at 3600 rPM
Head
98 to 245 feet at 3600 rPM
Liquid handled
Type of liquid
Clean water
Temperature
Maximum: 212°F (100°C)
Maximum: 250°F (121°C) with
optional high temperature seal
Working pressure
Maximum: 125 PSI (9 bar)
Materials
Casing
304L Stainless Steel
Impeller (closed type)
304L Stainless Steel
Shaft
304L Stainless Steel
bracket
Cast iron
Shaft Seal
Mechanical Seal – Type 21
High temperature version
Mild chemical version
Direction of Rotation
Clockwise when viewed from motor end
Motor
Type
NEMa 56J Frame
Speed
60 Hz, 3450 rPM (2 poles)
Single Phase
TEFC – 2 HP to 5 HP
ODP – 2 HP to 3 HP, 115/230V
Explosion proof – consult factory
Three Phase
TEFC – 2 HP to 5 HP
Washdown duty – consult factory
ODP – 2 HP to 3 HP, 208-230/460V
Motor Protection
built-in overload protection (single phase)
bearing
ball bearing
Model CDU, CDX, 2CDU, 2CDX
Ebara End Suction Centrifugal / Two-stage Centrifugal
instructions and Operation