Page 11: Troubleshooting caution

background image

Ebara Submersible Sewage Pumps

DLFU/DLFMU

Operating, Installation, and Maintenance

Ebara

Fluid Handling

www.pumpsebara.com

11

(803) 327-5005 • (803) 327-5097

fax

rev. 10/11

Troubleshooting

Caution

all service should be done by factory trained or qualified personnel only.

trouble

Cause

remedy

Does not start.

(1) Power failure

(1)-(3) Contact electric power company; devise counter-measures

Starts, but

(2) Large discrepancy between power source and voltage

immediately stops.

(3) Significant drop in voltage
(4) Motor phase malfunction

(4) Inspect connections and magnetic switch

(5) Electric circuit connection faulty

(5) Inspect electric circuit

(6) Faulty connection of control circuit

(6) Correct wiring

(7) blown fuse

(7) replace with correct type of fuse

(8) Faulty magnetic switch

(8) replace with correct type of magnetic switch

(9) Water is not at level indicated by float

(9) raise water level

(10) Float is not in appropriate level

(10) Move float to an appropriate starting level

(11) Float defective

(11) repair or replace

(12) Short circuit breaker is functioning

(12) repair location of short circuit

(13) Foreign matter clogging pump

(13) remove foreign matter

(14) Motor burned out

(14) repair or replace

(15) Motor bearing broken

(15) repair or replace

Operates, but stops

(1) Prolonged dry operation has activated motor protector (1) raise stop water level

after a while.

and caused pump to stop
(2) High liquid temperature has activated motor protector (2) Lower liquid temperature
and caused pump to stop

Does not pump.

(1) reverse rotation

(1) Correct rotation (see Operation 2, (3))

Inadequate volume.

(2) Significant drop in voltage

(2) Contact electric power company and devise
counter-measures

(3) Operating a 60Hz pump on 50Hz

(3) Check nameplate

(4) Discharge head is high

(4) recalculate and adjust

(5) Large piping loss

(5) recalculate and adjust

(6) Low operating water level causes air suction

(6) raise water level or lower pump

(7) Leaking from discharge piping

(7) Inspect, repair

(8) Clogging of discharge piping

(8) remove foreign matter

(9) Foreign Matter in suction inlet

(9) remove foreign matter

(10) Foreign matter clogging pump

(10) Disassemble and remove foreign matter

(11) Worn impeller

(11) replace impeller

Over current

(1) Unbalanced current and voltage

(1) Contact electric power company and devise counter-measure

(2) Significant voltage drop

(2) Contact electric power company and devise counter-measure

(3) Motor phase malfunction

(3) Inspect connections and magnetic switch

(4) Operating 50HZ pump on 60Hz

(4) Check nameplate

(5) reverse rotation

(5) Correct rotation (see Operation 2. (3))

(6) Low head; excessive volume of water

(6) replace pump with low head pump

(7) Foreign matter clogging pump

(7) Disassemble and remove foreign matter

(8) Motor bearing is worn or damaged

(8) replace bearing

Pump vibrates;

(1) reverse rotation

(1) Correct rotation

excessive operating

(2) Pump clogged with foreign matter

(2) Disassemble and remove foreign matter

noise.

(3) Piping resonates

(3) Improve piping

(4) Gate valve is closed too far

(4) Open gate valve