Pump Installation

1. Clean the installation area.

2. Under no circumstances should the cable be pulled while the pump is being

transported or installed. Attach a chain or rope to the grip and install the
pump.

3. This pump is NOT to be installed on its side. Ensure that it is installed upright

and on a secure base.

4. Install the pump at a location in the tank where there is the least turbulence.

5. If there is a flow of liquid inside the tank, support the cable where appropriate.

6. Install piping so that air will not be entrapped. If piping must be installed in

such a way that air pockets are unavoidable, install an air release valve
wherever such air pockets are most likely to develop.

7. Do not permit end of discharge piping to be submerged as backflow will

result when the pump is shut down.

8. Non-automatic pumps do not have an automatic operation system based on

built-in floats. Do not operate the pump for an extended period of time with
the water level near the minimum operation level as the automatic cut-off
switch is incorporated inside the motor will be activated.

EBARA

Fluid Handling

www.pumpsebara.com

13

(t) 803 327-5005 • (f) 803 327-5097

DWU, DWXU

Installation Instructions

WARNING

When lifting the pump, attach an appropriate lifting cable or rope
to the lifting handle before installation.

Do not lift the pump by the electrical cables.

Handle the cables very carefully. Excessive bending or pulling
may damage the cable and molded seal, resulting in insulation
failure. Protect cable ends against water intrusion.

CAUTION

Check rotation BEFORE installation. Correct rotation is clockwise when viewed from
top of the motor. Read ELECTRICAL WIRING.