Options for every application, Leed categories satisfied by the ucw/h system – ClimaCool UCW Water Cooled User Manual
Page 3

Options for every application.
Water Isolation Valves and Flush Ports
Factory installed to provide isolation to the module
for maintenance and cleaning of evaporator and
condenser heat exchangers. This is accomplished
without increasing unit or bank dimensions while
adjacent modules continue normal operation.
Optional choice of integral manual or motorized
valves includes ¾” fill and flush valves.
Condenser Water Head Pressure
Regulating Control
Factory installed
motorized condenser water valves provide head
pressure regulation for low entering condenser
water temperature applications (less than 60°F).
Hot Gas Bypass
Factory installed on both
circuits allowing unit operation below the minimum
step of unloading.
Heat Recovery
Factory installed option
that provides hot water, as high as 135°F, while
simultaneously producing chilled water for the
chiller system.
Heat Pump
Factory installed reverse cycle
heating and cooling operation compatible with
boiler/tower and geothermal systems.
Water Header Bypass
A field installed
water header bypass may be utilized to prevent
deadheading the pump.
Pressure Differential Flow Sensor
Field
installed to prevent operation of the chiller without
sufficient water flow to the evaporator and/or
condenser.
Automatic CS Series Strainer Package
Field installed high quality stainless steel filtration
systems with minimum 60 mesh stainless steel
screens. Available options include pressure
differential alarm and automatic time flush.
Manual Strainers
Field installed to increase
efficiency and ensure long life of the equipment with
Y-style and Basket strainers of cast iron 200 psi or
carbon 275 psi with 60 mesh stainless steel screens.
All strainers are field installed external to the chiller
bank for ease of service.
LEED categories satisfied by the
UCW/H system:
Sustainable Sites and Building Re-Use
Compact design shrinks mechanical room and
building footprint and allows modules to fit
through existing doors. This eliminates the need for
demolition and reconstruction.
Enhanced Commissioning and
Measurement and Verification
CoolLogic
Control System provides maximum flexibility with
BAS interface.
Optimized Energy Performance
Exceeds
ASHRAE 90.1 minimum efficiency.
Enhanced Refrigerant Management
Micro
charge of chlorine-free and non-ozone depleting
refrigerant.
Thermal Comfort
Precise required heating and
cooling ensures the highest comfort for building
occupants.