CEMB/TDSP SYSTEM/VERSION 1/05-10-10
2.
Intermediate structure
This solution extends the basic composition by using the ethernet link to interface all the
TDSP modules with an industrial PC for acquiring, displaying and saving data.
The composition for the basic structure has the following devices added:
-
1 switch for the ethernet connection of the various modules to the PC
-
1 industrial PC with suitable characteristics
This configuration is combined with a specific software package for managing and
presenting data in online mode and can display:
⇒
The values for the various magnitudes
⇒
The measurement trend
⇒
The status of the various measurements
⇒
Alarm indication
Measurement information is made available in real-time for third party applications as well,
using an OPC Server/Client type interface.
Where required, a further software package can be supplied for saving data (in a database