CEMB USA T1-40 ATEX User Manual
Page 3
T1-40-ATEX 04 gb
3
Notes concerning certification:
1) The use of ATEX certified transducers is not allowed for different hazardous conditions or for those
exceeding the data specified on the nameplate affixed to the transducer.
2) The transducer does not require maintenance. Any work regarding performance checks or repair
should only be carried out in a laboratory duly authorized by CEMB SpA.
Notes for the identification :
The TRANSDUCER is manufactured in various versions in order to be correctly used according to :
1) the dangerous Zones where they will be used (zone 0 and 1)
2) the operating temperature (ambient t. and maximum t.)
3) the ambient operating characteristics (suitable or less suitable atmospheres for
the following materials : STAINLESS STEEL, ALUMINIUM, PLASTIC)
These characteristics must match in order to meet ALL the plant requirements. The CEMB codes with
which the main versions are identified and which meet requirements as per points 1 to 3 are as follows:
CEMB Code
ZONE 0
9801145T4
TRANSDUCER T1-40/00/00/1C (-40÷+100°C)
II 1GD Ex ia IIC T4 Ex iaD 20 T135°C
+135°C SURFACE,
Zone 0, ATEX
9801145T5
TRANSDUCER T1-40/00/00/1B (-40÷+80°C)
II 1GD Ex ia IIC T5 Ex iaD 20 T100°C
+100°C SURFACE,
Zone 0, ATEX
9801145T6
TRANSDUCER T1-40/00/00/1A (-40÷+60°C)
II 1GD Ex ia IIC T6 Ex iaD 20 T85°C
+85°C SURFACE,
Zone 0, ATEX
CEMB Code
ZONE 1
9831145T4
TRANSDUCER T1-40/00/00/1N (-40÷+100°C)
II 2GD Ex ia IIC T4 Ex iaD 21 T135°C
+135°C SURFACE,
Zone1,ATEX
9831145T5
TRANSDUCER T1-40/00/00/1M (-40÷+80°C)
II 2GD Ex ia IIC T5 Ex iaD 21 T100°C
+100°C SURFACE,
Zone1,ATEX
9831145T6
TRANSDUCER T1-40/00/00/1L (-40÷+60°C)
II 2GD Ex ia IIC T6 Ex iaD 21 T85°C
+85°C SURFACE,
Zone 1,ATEX