2
Composition
Integrated transmitter body in stainless steel AISI 316L material
Power supply
24 Vdc (10 to 35 Vdc) current loop 4 to 20 mA (2 wires)
maximum load, as per figure 2
External connections
connector 2 poles MIL-C-5015 (conductors max section 2,5 mm²)
Environmental use field
- 50°C to + 120°C
IP 65 EN 60529/10.91 standard
Measure type
Omnidirectional Seismic (absolute vibrations)
Dynamic field
± 18 g
Transversal sensitivity
< 5 %
Linearity
± 2% - 75 Hz
Dynamic performances
±3% / 10Hz-1kHz (See figure 1)
-3db / 1.5Hz – 2.5kHz
Insulation
10
8
between signal and container
Application axis
any
Standard machine connection thread
M8x1,25
¼’’ – 18NPT
¼’’ – 28UNF
Maintenance
nothing
Electrical connections
bipolar shielded cable, conductors typical section 2x1mm²
Possible arrangements to the order
measuring field
fastening
Mounting torque
5÷10 N-m