beautypg.com

Wiring – Hunter 53134 52 Aventine User Manual

Page 10

background image

www.HunterFan.com

1.888.830.1326

Wiring

FRO

M FAN

FR

OM

CEILING BRA

CK

ET

FROM FAN

Using an orange wire

connector from

the hardware bag,

connect the 3 grounding

wires (green, green/

yellow stripe, or bare

copper) coming from the

ceiling, downrod, and

hanging bracket.

(G

rounding)

G

reen/Y

ello
w

Strip
e

Green/Yellow

Stripe

W

hit

e

Black

(G

rounded)

Note: To connect the wires,

hold the bare metal leads
together and place a wire

connector over them, then twist

clockwise until tight.

Using the orange wire

connectors from

the hardware bag, connect

the black wire (ungrounded)

from the ceiling to the black

and the blue wires from the

fan. Connect the white wire

(grounded) from the ceiling to

the white wire from the fan.

Using the orange wire

connectors from

the hardware bag,

connect the white wire

(grounded) from the

ceiling to the white wire

from the fan.

Connect the black wire

(ungrounded) from the

ceiling to the black wire

from the fan. Connect the

second (ungrounded) wire

from the ceiling to the blue

wire from the fan.

FROM FAN

Whit

e

(Ungr

ounded)

Black

Blue

(Grounded

)

FR

OM CEILING

(Ungrounded

)

Blue

For Dual Switches

For a Single Switch

FR

OM CEILING

FR

OM CEILING

Turn the splices upward and push them carefully back through the hanger bracket

into the outlet box. Spread the wires apart, with the grounded wires on one side of

the outlet box and the ungrounded wires on the other side of the outlet box.

Refer to CAUTION c.1 on pg. 2

10

M0043-01 • 01/29/14 • © Hunter Fan Company

(Ung

rounded)