6. If the bearings were loose, the tightening procedure could change the arm positioning.

Test the positioning of the arm by rolling it along the beam. It should roll smoothly the

whole way and be parallel to the tabletop.

6.2 Aligning the Arm

When your Castle Assembly Table is set up or reassembled after relocation, the arm must be

aligned to ensure proper operation.

Note: This procedure requires two people.

1. If the arm is not already on the table, remove the stop bolt on one end of the top beam

and slide the assembled arm onto the table.

2. Re-insert the stop bolt.

3. Loosen the four bolts on the top bracket that hold the arm in place while someone holds

the bottom bracket firmly in place on the table.

UPPER BRACKET ARM 

BOLTS 

Fig 21

UPPER BRACKET ARM 

BOLTS 

BEARING NUTS 

4. Do not loosen the bottom bracket bolts.

5. Adjust the arm in the upper bracket until the desired position is reached.

6. Tighten the bolts in the upper bracket.

7. Test the positioning by rolling the arm along the beam. It should roll smoothly across the

entire work top.

8. You may need to repeat steps 3 through 7 to achieve proper adjustment and smooth

functioning of the arm.