Operation, Faults – KOSPEL EPP Maximus User Manual

Page 13

background image

13

PL/DE/GB/FR/RU-051AB/f.422

Operation

The heater switches on automatically straight after

reaching the flow rate over 2,5 l/min. The tempera-

ture control system selects an appropriate heating

power depending on the rate of flow, temperature

setting (set with the use of a knob on the front case)

and the temperature of water in the mains.

There are two indicators on the case:

-

green – power supply “on”,

-

red – heating “on”.

If the red indicator starts to flicker when heating is

being switched “on”, it means that the water flow is

too high for the temperature setting (the flow or the

temperature set should be reduced).

If the red indicator flickers, when there is no heating (no flow through the heater), it

means that a failure of the temperature sensor has occurred.

If the red indicator is on for about 1 sec. and off for the next 3 sec., it means that

the heater is blocked by NA entry.

Faults

Repairing the above is not covered by the warranty. If the heater breaks down (and

it is caused by none of the above reasons) you need to contact distributor/seller.

If the following signals of faulty work are noticed, check for possible reasons:

Fault

Reason

if the indicators on the case

are off

the plug-in connector is not properly inserted [NAST],
there is a failure of power supplies,

if the heating is weak or it

does not heat at all

there is a failure of power supplies,

if the flow rate is not suf-

ficient

regulating valve has been incorrectly adjusted.