Ppe2, kde2, ppve configuration ppe2 operation – KOSPEL KDE User Manual
Page 23
23
PL,DE,GB,RU-045AB/f.453
PPE2, KDE2, PPVE Configuration
PPE2 Operation
Before you supply voltage to the unit for the first time,
make sure that you set the unit’s power at appropriate
value (always consider the capacity of your home’s
electrical system). Set the switches (located at the
bottom of electronic board) at appropriate position to
configurate the unit.
1-6 Switches setting (the grey square shows the
switch position):
•
1, 2 - rated power of unit,
•
3, 4 - size of heating box,
•
5 - ON - switch position that activates the air
control at the heating box,
•
6 - ON - switch no. 6 in „ON” position blocks ac-
cess to the unit’s setting (this realtes to PPE2 and
PPVE only). In this case, the LED display shows
the desired temperature value (which has been
adjusted before the unit start-up), the heating icon
and other possible working characteristics.
The heater switches on automatically straight after
reaching the flow rate over 2,5 l/min. The temperature
control system adjusts the power rate according to
the water flow rate, required temperature and the
temperature of water in the mains. The LCD backlight
and icon signalises the heating operation.
If the unit reach the maximum power value which
is too low for a given operating conditions the LCD
display will show „INSUF POWER’’. The LED display backlight also turns on while
pushing or turning the setting knob. The backlight will automatically turn off when
the heating operation is turned off, or if more than 50 seconds have passed since
the last adjustment.
If you block the unit by master appliance (NA entry) the display will show
„NA BLOCK”
If the fault occurs the display will show icon and error message.
Error messages:
Heating box size 15 kW
Heating box size 24 kW
Heating box size 27 kW