Performance curve, Dimensions, Typical installation specifications – All-Flo KN-5 1/2 Classic PVDF User Manual
Page 2: Metallic, Plastic do not use air line lubrication
AIR FLOW CONTROL
VALVE IS OPTIONAL
(USE TO MAINTAIN
MAXIMUM AIR
EFFICIENCY)
AIR FLOW CONTROL
VALVE PART NO:
13400-30
Muffler (air exhaust)
is supplied with
each pump.
DISCHARGE
SUCTION
Flexible Airline
SUCTION AND DISCHARGE PORTS
CAN BE REPOSITIONED TO SUIT
THE APPLICATION
PERFORMANCE CURVE
(Based on water-flooded suction)
0
6
10
2
DISCHARGE FLOW-Liters/Min.
7,6
15,2
60,8
20
(1,3)
40
(2,7)
60
(4,1)
80
(5,4)
100
(6,8)
230
(69,9)
184
(55,9)
138
(41,9)
92
(27,9)
46
(13,9)
T
O
T
A
L
HEAD IN FEET (METERS)
PRESSURE INLET/OUTLET PSIG (BAR)
15
5
2
10
DISCHARGE FLOW-U.S. Gals./Min.
53,2
22,8
30,4
45,6
38,0
4
8
12
14
16
AIR CONSUMPTION - SCFM
8.34
(212,0)
AIR INLET
10.86
(276,0)
7.82
(198,6)
4.40
(112,0)
DISCHARGE
INLET
4.00
(102,0)
7.50*
(190,5)
4.14
(105,0)
AIR
EXHAUST
0.28 DIA-4 SLOTS
(7,0)
5.21
(132,0)
28.6
(1,13)
3.24
(82,0)
5.40
(137,0)
5.43
(138,0)
10.75
(273,0)
AIR INLET
9.76
(248,0)
9.38
(238,0)
5.70
(145,0)
DISCHARGE
SUCTION
4.00
(102,0)
7.50*
(190,5)
5.12
(130,0)
AIR
EXHAUST
0.31 DIA-4 SLOTS
(8,0)
6.19
(157,2)
1.38
(35,0)
3.26
(83,0)
6.70
(170,0)
Metallic
DIMENSIONS
Dimensions in inches and (mm)
Plastic
DO NOT USE AIR LINE LUBRICATION
Typical Installation
SPECIFICATIONS
CAPACITY
Adjustable 0-14 GPM (53,2 LPM)
MAXIMUM TEMP:
PVDF models – 200˚F (93˚C)
Other plastic models – 150˚F (66˚C)
Metallic models – 200˚F (93˚C)
MAXIMUM AIR PRESSURE:
100 psi (6,8 bar)
MINIMUM AIR PRESSURE:
20 psi (1,3 bar)
DRY LIFT:
Models with PTFE balls – 10 feet (3 meters)
Other models – 15 feet (4,5 meters)
WEIGHT:
PVDF models – 11 lbs. (5 kg)
Other plastic models – 8 lbs. (3,6 kg)
Aluminum models – 8.5 lbs. (3,8 kg)
SS models – 16 lbs. (7,2 kg)
MAXIMUM SOLIDS:
1/8" (3,2 mm)
AIR SUPPLY:
Inlet – 1/4" NPT Female (BSP compatible)
Outlet – 3/8" NPT Female
FLUID INLET/DISCHARGE:
1/2" NPS Female
(BSP or NPT compatible)