10

[CN5] Front Failure LED Connector

Pin

Def.

1

Failure LED+

2

N/A

3

Failure LED-

4

Mute+

5

Key Pin

6

Mute-

DIP Switch Function for Fan/Temp.

[SW1 (1)]

Fan1 Detection Enable/Disable SW1-1

Enable

ON

Disable

OFF

[SW1 (2)]

Fan2 Detection Enable/Disable SW1-2

Enable

ON

Disable

OFF

[SW1 (3)]

Temperature Setting SW1-3

65 Degree C

ON

55 Degree C

OFF

DIP Switch Function for SGPIO

[SW2 (1)]

SGPIO function setting

(HDD activity Enable/Disable)

SW2-1

Enable

ON

Disable

OFF

[SW2 (2)]

SGPIO function setting

(HDD failure Enable/Disable)

SW2-2

Enable

ON

Disable

OFF