P/N VDC24041-AA-Sx-MNL

large or too deeply discharged to be fully charged in the normal

time allowed by charger. If you are certain battery is not defective,

having read and understood completely all of the above concerns

and conditions, proceed to reboot the charger by unplugging from

the wall (A.C.), disconnecting from the battery (D.C.) and waiting 10

seconds before reconnecting the battery and then the A.C. This

allows charger to begin charging battery again. If battery is not

defective it should be able to be fully charged after being restarted.

After sufficient time has lapsed the

GREEN charge LED Indicator will

blink confirming when / if battery is now fully charged.

Note: If attempting to charge more than one battery at a time, it is

very likely the charger will need to be restarted as described in order

to completely charge multiple batteries. We do not recommend

charging more than one battery at a time. A better solution is to

charge each battery separately using your BatteryMINDer and

then connect them together, if desired for long term maintenance-

float charging. We suggest reading

MAINTAINING MULTIPLE

BATTERIES,

page 18, and the additional LED Indicator Functions,

page 11, not already covered above.

IMPORTANT!

Charging a Battery in a Tightly Confined Area

Charging a battery in a tightly confined area should always be

avoided as it can be dangerous, especially if battery is, has or

was:

1.

Older than 2 years

2.

Infrequently used without an approved maintenance aviation

specific charger being consistently used

3.

Marginal at last capacity test

4.

Not frequently checked for proper electrolyte level in each cell

5.

Ever needed considerable water added, especially in one or

more cells vs. other cells needing far less

6.

Different Specific Gravity (SG) readings-levels (cell to cell) or

has one or more cells reading less than 1.220 after being fully

charged, left to “Rest”

1

for a minimum of 12 hours (as we describe

repeatedly in all our Instruction Manuals)

WE NO LONGER ADVISE USE OF THE RING TERMINAL