Borg Locks BL 200 Series User Manual
Borg locks, Bl200, Series programming instructions
Helpline: 0800 44 88 377
www.borglocks.com
Contents
controlling access
Borglocks
BL200
Series
Programming Instructions
1. Keypad
2. Override Keys
3. Offset Cam (47mm)
4. Straight Cam (45mm)
5. Straight Cam (35mm)
6. Spacer
7. Spacer Cap
8. M4 Fixing Screws (25mm)
9. M4 Fixing Screws (12mm)
10. M5 Cam Screw (25mm)
11. M5 Cam Screw (5mm)
Program Step 08 - Passage Mode On
08
●
08
● ●
Result: Lock will be continuously unlocked
Program Step 07 - Restore all user codes
07
●
07
● ●
Result: All user codes restored
Program Step 09 - Passage Mode Off
09
●
09
● ●
Result: Lock will be continuously locked
(code required)
Program Step 10 - Change Unlock Time
10
●
enter open time (range 1-9 seconds)
● ●
Result: After code entry the lock will unlock for the set time
Program Step 11 - Locked/Unlocked Status Indicator
1. No LED’s flashing = Locked or unlocked (this is the default status)
2. Red LED flashing = Locked
3. Blue LED flashing = Unlocked
4. Red LED flashing = Locked and blue LED flashing = unlocked
Result = LED’s to flash once every 5 seconds
11
●
1
● ●
Result: No LED flashing = locked or unlocked
Blue LED flashing = unlocked
11
●
3
● ●
Result: Blue LED flashing = unlocked
11
●
4
● ●
Result: Red LED flashing = locked
11
●
2
● ●
Result: Red LED flashing = locked
Program Step 20 - Change Master Code
Result = Master code now changed to #123456.
20
●
Length of new master code
●
new master code
●
length
of new master code
●
new master code
● ●
Example: 20
●
6
●
123456
●
6
●
123456
● ●
Please note = If the length of the master code is changed then
all previous sub-master code and user codes will be deleted.
Program Step 21 - Delete sub-master code
21
●
21
● ●
Result: Sub-master code has been deleted
Program Step 22 - Changing from single-use to repeat-use
mode (default)
Result = A factory set reopeat-use user code 12345 will work repeatedly
allowing the user to unlock the lock unlimited times using the same code
22
●
22
● ●
Please note = When the lock operation is changed from single-use, user
code above to repeat-use user code the lock will lock and the previous
single-use user code will be deleted.
Program Step 23 - Changing from repeat-use to single-use
mode
Result = The lock will now work in the single-use user code mode
23
●
23
● ●
Please note = The lock is now programmed to be unlocked when using the
above code and is ready and waiting to accept a new single-use user code.
Program Step 30 - Reverting All to Factory Settings
30
●
30
● ●
Result = After code entry the lock memory can be
cleared and made to revert to all factory default settings.
User code Self-Change
# user code
● ●
new user code
●
new user code
● ●
Example: #2111
● ●
5541
●
5541
● ●
Result: User code is now 5541
Please note: The (
● ●
)
double blue LED after a successful
code sequence for all of the above sequences.
User ID
User Name
Code
01
02
03
04
05
06
07
08
09
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
Record of Users
2
3
4
5
6
7
8
9
10
11
1
2
3
4
5
6
7
8
9
0
C
#
1
Borglocks