7.1 High temp.life test

Temperature +85

±3℃

Duration 72hrs

7.2 Low temp.life test

Temperature -40

±3℃

Duration 72hrs

7.3 Heat Cycle Test

Temperature +85

±3℃ 1hour

-40

±3℃ 1hour

Cycles 10cycles

7.4 Humidity Test

Temperature +60

±2℃

Relative Humidity 90~95%
Duration 72hrs
Tests above should be measured after leaving normal temperature for24hrs.

7.5 Vibration Test

Vibration Frequency 10~55Hz
Sweep Period 1min
Amplitude(peak to peak) 1.5mm
Direction 3(x.y&z)
Time 2hours/direction

7.6 Shock test

Acceleration sine 100G
Direction 3directions
Shock time 3 time/directions

7.7 Drop test

Height 1m on concrete floor
Times 10times

7.8 Connector soldering check:

Immersing terminal up to 1mm below base in soldering bath at 260℃ 10 seconds
Notice:
The variation of the S.P.L or the sensitivity at 40KHz is within 3dB compared with

initial figures at 25℃ in 24 hours after above test condition.

Approved by:

Checked by:

BESTAR ELECTRONICS INDUSTRY CO.,LTD

4

Note

耿 亚

Drawn by:

Date:

Page:6 of 9

DRG NO:BS/TEU01.302C

邹皓轩

www.be-star.com [email protected]

3

Ultrasonic Sensor

2

1

倪雪晴

BPU1640IOAH12

A

B

7.Reliability Test

BPU1640IOAH12

4

D

F

E

3

1

2

H

G

李红元

C

倪雪晴

10.11.19

10.11.19

Acous tics & Sensor