beautypg.com

Reliability test, Bestar electronics industry co.,ltd – BeStar BPU1640T_ROPBH12 User Manual

Page 6

background image

倪雪晴

2010.12.15

H

G

F

1

2

3

D

C

B

E

4

5

6

7.Reliability Test

H

G

F

BPU1640T/ROPBH12

D

C

B

T

h

is

p

ri

n

t

a

n

d

i

n

fo

rm

a

tio

n

t

he

re

i

n

a

re

p

ro

p

ri

e

ta

ry

t

o

B

e

s

ta

r

E

le

c

tr

o

n

ics

I

ndu

s

tr

y

C

o

.,

L

td.

a

nd

s

h

a

ll

no

t

b

e

u

s

ed

i

n

w

h

o

le

o

r

in

pa

rt

w

ith

ou

t

it

s

w

ri

tt

en

c

on

tent

E

7.1 High temp.life test

Temperature +85

±3℃

Duration 100hrs

7.2 Low temp.life test

Temperature -40

±3℃

Duration 100hrs

7.3 Heat Cycle Test

Temperature +85

±3℃ 1hour

-40

±3℃ 1hour

Cycles 10cycles

7.4 Humidity Test

Temperature +60

±2℃

Relative Humidity 90~95%
Duration 100hrs
Tests above should be measured after leaving normal temperature for24hrs.

7.5 Vibration Test

Vibration Frequency 10~55Hz
Sweep Period 1min
Amplitude(peak to peak) 1.5mm
Direction 3(x.y&z)
Time 2hours/direction

7.6 Shock test

Acceleration sine 100G
Direction 3directions
Shock time 3 time/directions

7.7 Drop test

Height 1m on concrete floor
Times 2times

7.8 Connector soldering check:

Immersing terminal up to 1mm below base in soldering bath at 260℃ 10 seconds

Notice:
The variation of the S.P.L or the sensitivity at 40KHz is within 3dB compared with

initial figures at 25℃ in 24 hours after above test condition.

A

Ultrasonic Sensor

BPU1640T/ROPBH12

2

1

倪雪晴

邹皓轩

李红元

3

Page:6 of 9

Approved by:

Checked by:

Drawn by:

Note

4

Drawn

Date

6

5

A

Rev.

A

BESTAR ELECTRONICS INDUSTRY CO.,LTD

www.be-star.com [email protected]

Date:

2010.12.15

DRG NO: BS/TEU01.009A

Acous tics & Sensor