Microphone, Reliability test, 85 c – BeStar BCM6022OLFC-40 User Manual
Page 4: 20 c, 20 c -40 c

C
C
Drawn
A
Rev.
6
Date
B
Approved by:
Checked by:
Note
5
4
Date:
Drawn by:
3
2
A
Page:4 of 6
1
B
T
h
is
p
ri
n
t
a
n
d
i
n
fo
rm
a
tio
n
t
he
re
i
n
a
re
p
ro
p
ri
e
ta
ry
t
o
B
e
s
ta
r
E
le
c
tr
o
n
ics
I
ndu
s
tr
y
C
o
.,
L
td.
a
nd
s
h
a
ll
no
t
b
e
u
s
ed
i
n
w
h
o
le
o
r
in
pa
rt
w
ith
ou
t
it
s
w
ri
tt
en
c
on
tent
D
E
F
G
H
6
5
4
3
2
D
E
F
G
1
H
09.06.29
DRG NO:
4.1 High temp.life test
 Temperature +85
°C
 Duration 100hrs
4.2 Low temp.life test
 Temperature -40
°C
 Duration 100hrs
4.3 Temperature cycle test
 Cycles 10
4.4 Humidity Test
 Temperature +40
°C
 Relative Humidity 90~95%
 Duration 48hrs
 Tests above should be measured after leaving normal temperature for 6hrs.
4.5 Vibration Test
 Vibration Frequency 10~55Hz
 Amplitude 1.52mm/min
 Direction 3(x.y&z)
 Duration 2hrs each cycle(total 6 hrs)
4.6 Drop test
 Height 1m
 (Dropped to 20mm thick hardwood board without packing.)
 Direction 3
4.7 Soldering Heat Shock .
 Temperature 260
±5°c
Duration 2
±0.5 sec
4.8 Terminal Mechanical Strength
 Strength 1kg
 Duration 1 min
 Notice:
 All specifications must be satisfied in this condition.
 Sensitivity :Allowable deviation within 
±3dB from initial sensitivity.
BCM6022OLFC-40
4.Reliability Test
1hrs
+85 C
1hrs
1hrs
1hrs
+20 C
+20 C
-40 C
BCM6022OLFC-40
Microphone
徐 波
陶红仲
B
王丽娟
A
李红元
05.05.21
BS/TEM01.112B
09.06.29
徐 波
博 士 達
