Reliability test, Recommended temp. profile for reflow oven, Bestar electronics industry co.,ltd – BeStar FT-12H-5.5B1 User Manual
Page 4: C30 10s, 李红元 赵 峥 汤浩君 汤浩君
FT-12H-5.5B1
DRG NO: BS/TEY01.266A
FT-12H-5.5B1
Piezo Ceramic Element
T
h
is
p
ri
n
t
a
n
d
i
n
fo
rm
a
tio
n
t
he
re
i
n
a
re
p
ro
p
ri
e
ta
ry
t
o
B
e
s
ta
r
E
le
c
tr
o
n
ics
I
ndu
s
tr
y
C
o
.,
L
td.
a
nd
s
h
a
ll
no
t
b
e
u
s
ed
i
n
w
h
o
le
o
r
in
pa
rt
w
ith
ou
t
it
s
w
ri
tt
en
c
on
tent
B
C
D
E
F
G
H
A
Rev.
BESTAR ELECTRONICS INDUSTRY CO.,LTD
5
6
4
3
Drawn
Date
Note
Drawn by:
Approved by:
Checked by:
Date:
Page: 04 of 05
1
2
A
B
C
D
E
F
G
H
1
5
6
4
3
2
5.Reliability Test:
5.1.High Temperature Test
Temperture +80 C
Duration 96hrs
5.2.Low Temperature Test
Temperature -30 C
Duration 96hrs
5.3.Temperature Cycle Test
Cycles 5
5.4.Humidity
Temperature 40 2 C
Relative Humidity 90~95R.H.
Duration 240hrs
+20 C
+20 C
15min
30min
15min
30min
-20 C
+70 C
all these tests above should be measured after leaving normal temperature for 2hrs.
5.5.Vibration Test
Vibration Frequency 10~55Hz
Amplitude 1.52mm
Duration 2 hrs each of 3 axis
5.6.Shock
Piezoelectric disc shall be measured after applying shock at (980m/s
2
) for each three mutually
perpendicular (XYZ) directions by half sine waves,3 times eac h
250 10
°C
230 5
C
200
C
10 1s
90 3s
150 10
C
30 10s
5.7. Recommended Temp. Profile for Reflow Oven
李红元
赵 峥
汤浩君
汤浩君
08/12/29
08/12/29
A