beautypg.com

Characteristics, Measuring method, Bestar electronics industry co.,ltd – BeStar FT-27T-4.3A1 User Manual

Page 3: 郭 敏 姜文金 杨红烨 杨红烨

background image

郭 敏

姜文金

杨红烨

杨红烨

06/08/24

06/08/24

FT-27T-4.3A1

Fig.3.2 Direction of Lead Wire

Lead Wire

3.Characteristics:

Lead Wire

Fig.3.1 Direction of Lead Wire

90

°

3.2 Lead pull off test

a) Wire to be soldered on ceramic at the edge. It should withstand minimum 20N force applied in 180° .The

wire should not come out before this .The ceramic can be either glued on a surface of can be held in

hand.(Fig.3.2)

b) Wire to be soldered on ceramic at the edage&should be pulled up at 90° The element should be hold on

bottom and wire should be pulled up .It should withstand at least for 2.5N force(Fig.3.1)

3.1 Solderability

280 10 CTemperaure of Merited Solder,2 0.5sec Duration of Dipping .

T

h

is

p

ri

n

t

and

i

n

fo

rm

a

ti

on

t

he

re

i

n

a

re

p

rop

ri

e

ta

ry

t

o

B

e

s

ta

r E

le

c

tr

on

ics

I

ndu

s

tr

y

C

o

.,

L

td

.

and

s

ha

ll

no

t

be

u

s

ed

i

n

w

ho

le

o

r

in

p

a

rt

w

it

hou

t

it

s

wr

itt

en

c

on

tent

B

C

D

E

F

G

H

DRG NO: BS/TEY01.116B

A

Rev.

B

BESTAR ELECTRONICS INDUSTRY CO.,LTD

5

6

www.be-star.com [email protected]

4

3

Drawn

Date

Note

Drawn by:

Approved by:

Checked by:

Date:

Page:2 of 4

1

2

Piezo Ceramic Element

FT-27T-4.3A1

A

B

C

D

E

F

G

H

1

5

6

4

3

2

4.Measuring Method

4.1.Resonant Frequency/ Resonant Impedance:

Piezoelectric disc shall be clamped at a node or edge point ,figure to be free from any mechanical

stresses,and measure its resonant frequency and resonant impedance by using vector impedance analyzer

or equivalent.

Input frequency shall be swept within 1 to 5 kHz, where the resonant frequency is defined and the frequency

where the impedance shows minimum value, this impedance shall be the resonant impedance.

4.2.Capacitance:

A electrostatic capacity capacitance shall be measured at 120Hz by using LCR meter, such as DF2812A

LCR number bridge or equivalent. The part shall be clamped in the same way as the measurement of

resonant frequency / resonant impedance mentioned in section 4.1.

4.3.Insulation Resistance:

An insulation resistance shall be measured by using an insulation resistance meter,suach as DF2863

insulation resistance meter.

4.4.Measureing Condition:

Parts shall be measured under a condition(Temperature:+5 C to +35 C,Humidity:45 to 85% R.H.)

unless the standard condition(Temperature:+25 3 C,Humidity:60 10%R.H.)is redulated to