Piezo Ceramic Element
A
A
Rev.
6
5
Date
Drawn
Approved by:
4
Note
3
李红元
BDRG NO: BS/TEY01.228A
2
1
Page:04 of 08
3.3.Insulation Resistance:
An insulation resistance shall be measured by using an insulation resistance
meter,suach as DF2863 insulation resistance meter.
A
09/03/11
汤浩君
B
C
D
Checked by:
Drawn by:
Date:
09/03/11
耿 亚
汤浩君
FT-50T-0.87A1W130
B
C
D
3.1.Resonant Frequency/Resonant Impedance
piezoelectric diaphragm shall be clamped at a node point as shown in following figure to be free from any
mechanical stress,and measured its resonant frequency and resonant impedance by using
YW2788 synthesis parameter test apparatus or equivalent
3.2.Capacitance:
An electrostatic capacity capacitance shall be measured at 120Hz by using LCR meter, such as DF2812A
LCR numerical bridge or equivalent.the part shall be clamped at the node .
E
F
G
E
F
G
FT-50T-0.87A1W130
3.Measuring Method
H
6
5
4
3
H
2
1