3.5 Life test in normal temperature

Power supply Rated voltage
Duration 1000hrs

3.6 Solderability

Temperature of soldering pot 250±5°C
Duration 3±0.5sec

3.7 Drop test

Height 70cm
(to 10mm thickness woodenboard)
Direction 3

Notice: All specifications must be satisfied in this condition.

6

5

4

3

2

1

Note

BESTAR ELECTRONICS INDUSTRY CO.,LTD

Date

A

REV.

Drawn

B

C

Date:

www.be-star.com [email protected]

Approved by:

Checked by:

Drawn by:

Piezo Sounder

Page:3 of 5

A

B

C

3.1 High temperature test

Temperature +80°C
Duration 96hrs

3.2 Low temperature test

Temperature -30°C
Duration 96hrs

3.3 Temperature cycle test

Cycles 5

3.4 Humidity cycle test

Cycles 5

1h

15min

All these tests above should be measured after leaving normal temperature for 2hrs.

25 C 90-95% RH

D

10h

30min

E

F

-30°C

+20°C

12h

1h

D

30min 15min

65 C 90-95% RH

+80°C

+20°C

E

F

G

3.Reliability Test

5

6

H

G

2

3

4

1

H

B

赵 峥

A

BPT1405H07 LF

07/12/14

王善梅

07/12/14

BPT1405H07 LF

DRG NO: BS/TEP01.010B

赵 峥

陶红仲

张秀琴