Reliability test, Bestar electronics industry co.,ltd, Piezo sounder – BeStar BSP1313-05H2.5-02 LF User Manual
Page 4
3. Reliability test
3.1 high temperature test
Temperature +105 C
Duration 240hrs
3.2 low temperature test
Temperature -40 C
Duration 240hrs
3.3temperature cycle test
3.5 Vibration Test
Vibration Frequency
10~55Hz
Amplitude 1.52mm
Duration 2hrs each of 3 axis
3.6 Drop test
Height 100cm
(to 10mm thickness woodenboard)
Direction 3
3.7 Solderability
Temperature 255 5 C
Duration 3 0.5sec
3.8 Operating Life
Rated input voltage and frequency
Duration 96hours
3.9 Shock
Sounder shall be measured after being applied shock(100m/s 2)for each three mutually
perpendicular directions to each of 3 times by half sine wave
3.10 Lead pull
The part shall be pushed with a force of 9.8N for 10±1 seconds behind the part
Notice: All specification must be satisfied in this condition.
SPL: allowable deviation 5dB of the initial value after testing
Cycles 5
3.4 Humidity test
Temperature +40 C
Relative Humidity 90~95%
Duration 240hrs
all these tests above should be measured after leaving normal temperature for 2hrs.
15min
30min
30min
15min
-40 C
+20 C
+105 C
+20 C
REV.
Drawn
Date
6
5
A
Piezo Sounder
Date:
Note
Approved by:
4
Drawn by:
Checked by:
3
2
Page:3 of 6
1
A
B
C
D
E
F
G
H
B
C
T
h
is
p
ri
n
t
and
i
n
fo
rm
a
ti
on
t
he
re
i
n
a
re
p
rop
ri
e
ta
ry
t
o
B
e
s
ta
r E
le
c
tr
on
ics
I
ndu
s
tr
y
C
o
.,
L
td
.
and
s
ha
ll
no
t
be
u
s
ed
i
n
w
ho
le
o
r
in
p
a
rt
w
it
hou
t
it
s
wr
itt
en
c
on
tent
D
E
F
G
H
5
6
4
2
3
1
BESTAR ELECTRONICS INDUSTRY CO.,LTD
BSP1313-05H2.5-02 LF
A
07/11/29
赵 峥
07/11/29
赵 峥
陶红仲
张秀琴
BSP1313-05H2.5-02 LF
DRG NO: BS/TEP01.534A