beautypg.com

Reliability test, Transducer, 1h 12h – BeStar SMT1212-03XH10 LF User Manual

Page 3: 15min 30min, 30min 15min

background image

3.6 Vibration Test

Vibration Frequency 10~55Hz
Amplitude 1.53mm
Direction 3(x.y&z)
Duration 2hrs each direction (total 6 hrs)

3.7 Drop test

Height 70cm
(to 10mm thickness woodenboard)
Direction 3(x.y&z)

3.8 Solderability Test

1. Hand soldering system
Soldering Temperature 245 C
Duration 3 sec

DRG NO: BS/TET01.363E

Page: 3 of 7

www.be-star.com [email protected]

6

5

4

3

2

1

A

Rev.

Date

Drawn by:

Note

Drawn

Approved by:

Checked by:

Date:

B

A

SMT1212-03XH10 LF

Transducer

B

3.1 High temperature storage test

Temperature +90 C
Duration 96hrs

3.2 Low temperature storage test

Temperature -40 C
Duration 96hrs

3.3 Life test in normal temperature

Power supply Rated voltage
Duration 1000hrs

3.4 Temperature cycle test

Cycles 5

3.5 Humidity cycle test

Cycles 5

T

h

is

p

ri

n

t

a

n

d

i

n

fo

rm

a

ti

o

n

t

h

e

re

i

n

a

re

p

ro

p

ri

e

ta

ry

t

o

B

e

s

ta

r

E

le

c

tr

o

n

ic

s

I

n

d

u

s

tr

y

C

o

.,

L

td

.

a

n

d

s

h

a

ll

n

o

t

b

e

u

s

e

d

i

n

w

h

o

le

o

r

in

p

a

rt

w

it

h

o

u

t

it

s

w

ri

tt

e

n

c

o

n

te

n

t

1h

12h

All these tests above should be measured after leaving normal temperature for 2hrs.

C

D

10h

25

90-95% RH

1h

C

D

+20

+20

E

65

90-95% RH

15min

30min

-40

30min

15min

F

+90

E

F

1

2

3

4

5

6

G

SMT1212-03XH10 LF

3.Reliability Test

H

G

H

赵 峥

徐 波

11/12/15

C

06/08/07

韩学慧

D

11/12/15

徐 波

06/09/11

韩学慧

E

博 士 達

Acoustics &Sensor