Technical data – KOSPEL SW Termo Max User Manual
Page 25
25
PL/DE/FR/GB/RU-036_f.441
Technical data
*80/10/45
0
C
**55/10/45
0
C
*** constant water temp.(60
0
C).
Domestic hot water cylinder
SW
SW; SWZ SB; SBZ
Storage capacity
l
100
120
140
200
250
300
400
Rated pressure
tank
MPa
0,6
coil
1
Rated temperature
°C
80
SB; SBZ
Upper coil surface area m
2
-
0,75
0,8
0,9
Upper coil capacity
dm
3
-
4,5
5
5,5
Upper coil power
kW
-
29*
31*
34*
10**
10**
11**
Upper coil efficiency
l/h
-
714*
756*
838*
234**
248**
277**
Lower coil surface area
m
2
0,8
1,0
1,1
1,2
1,0
1,5
1,7
Lower coil capacity
dm
3
3,6
4,3
6,4
7,4 5,8 9,1
10
Lower coil power
kW
34*
41*
40*
44* 37* 53*
58*
11**
13**
13**
15**
12**
18**
20**
Lower coil efficiency
l/h
825*
1000*
996* 1071* 918* 1293*
1420*
271**
331**
332** 358**304** 435**
483**
24hrs electricity losses***
kWh
1,2
1,3
1,4
2
2,1
2,7
2,4
Weight (without water)
kg
46
52
54,5 82 97 87 99 100,5 115 132 150
Dimensions
A
mm
111
127
124
B
214
258
241
254
C
727
822
813
740
628
852
856
D
-
- 903 - 747 - 981 - 986
E
817
912
913
993
841 837 953 1071 9861076
F
-
-
1291
- 1079 - 1313 - 1319
G
1064 1235 1305
1464
1230
1646
1490
H
1195
1365 1435
1610
1380
1615
1660
I
-
1334
1116
1350
1377
3/4” ø22 Magnesium anode
mm
500
800
-
M8 ø33 Magnesium anode
-
450
-
-
M8 ø40 Magnesium anode
-
-
400
400
500
500
- heating water temp./ supply water temp./ domestic water temp, flow rate of
heating water through the coil -3m
3
/h.
}
GB