Technical data

Faults

In case the unit does not heat the water, check for the possible reasons:

The guarantee does not cover the above repairs.

If there is a fault in the unit (the heater does not work and all the above reasons do

not occur), contact the nearest authorised service.

EPO water heater

4

5

6

Rated power

kW

4

5

6

Power consumption

kW

2 + 2

2,5 + 2,5

3 + 3

Rated voltage

230V~ / 400V 2N~

Rated current

A

17,4 (8,7)*

21,7 (10,9)*

26,1 (13,0)*

Supply water pressure

MPa

0,12 ÷ 0,6

Operating point

l/min

1,2

1,5

1,8

Efficiency (at Δt = 30°C)

l/min

1,9

2,4

2,9

Overall dimension (height x width x depth)

mm

209 x 229 x 85

Weight

kg

~2,4

Fuse rated current

A

20 (10)*

25 (16)*

32 (16)*

Min. connecting wires section

mm

2

3x2,5 (4x1,5)*

3x4 (4x2,5)*

The maximum allowed network impedance

(0,32)**

(0,29)**

Water supply pipe section

G 1/2” (distance between inlet and outlet 110mm)

* - for 400V2N~

** - for 230V~

Fault

Reason

control lights off

power supply failure

unit doesn’t heat up the water/

water temp. is too low

power supply failure
water flow rate is too low (e.g. filter is blocked with impurities,

improper water flow regulation)
there is no bridge connecting terminal clamps U and V
for single phase supply