Anest Iwata LPH101-LVG User Manual
Lph-101-lv, Instruction manual, Important specifications

-
1 -
■Important specifications
Max. Pressure
0.68MPa
/ 6.8 b a r / 98 PSI
Noise level
76.1
d B (A)
Spray condition
Recommended
Measuring point
1m backwards from gun , 1.6m height
HVLP Compliant Spray Gun
LOW VOLUME LOW PRESSURE
Important
Be sure to observe warnings and cautions in this instruction manual.
If not, it can cause paint ejection and serious bodily injury by drawing organic solvent.
Be sure to observe following marked items which are especially important.
WARNING
Indicates a potentially hazardous situation which, if not avoided, may result in serious injury or loss of life.
CAUTION
Indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate injury or property
damage.
Important
Indicates notes which we ask you to observe. The safety precautions in this instruction manual are the minimum
necessary conditions. Follow national and local regulations regarding fire prevention, electricity and safety as well as
your own company regulations.
■Main specifications
※
1. Atomizing air pressure means air pressure at gun inlet when trigger is pulled and air flows.
※
2. Tested with 12 sec/NK-2 automotive repair paint.
This Anest-iwata spray gun kit complies to ATEX
regulations 94/9/EC,
Protection level :
Ⅱ
2 G X,Suitable for use in Zones 1 and 2.
X marking :
Any static electricity discharge from the spray gun
is to be diverted to the grounded the conductive
air hose as stipulated.
LPH-101-LV
INSTRUCTION MANUAL
This manual contains IMPORTANT WARNINGS and INSTRUCTIONS.
Equipment in this manual is exclusively for painting purposes.
Do not use for other purposes.
The operator shall be fully conversant with the requirements stated in this
instruction manual including important warnings, cautions and operation and
correct handling.
Read and understand the instruction manual, before use and retain for
reference.
Max. Temperature
Atmosphere
5℃~40℃
Air・Fluid
5℃~43℃
和文取説は、裏面にあります
Recommended condition
Model
Type of
feed
Nozzle
orifice
φ
mm (in)
Air cap
Set
Mark
※
1 Atomizing
air pressure
MPa (bar /PSI)
Air pressure
inside air cap
MPa (bar/PSI)
Fluid output
ml/min
Air
consumption
l/min (cfm)
Pattern
Width
Mm (in)
Air & fluid
Connection
Mass
g (lbs)
0.10 (1.0 /14)
0.05
(0.5 /7.1) ※2 80
200 (7.1)
※
2 170 (6.7)
LPH-101 -124LVG
1.2 (0.047)
0.13 (1.3 /18)
0.07
(0.7 /10)
70
240 (8.5)
190 (7.5)
0.10 (1.0 /14)
0.05
(0.5 /7.1) ※2 130
200 (7.1)
※
2 200 (7.9)
-144LVG
1.4 (0.055)
80
240 (8.5)
200 (7.9)
-164LVG
Gravity
1.6 (0.063)
0.13 (1.3 /18)
0.07
(0.7 /10)
100
240 (8.5)
220 (8.7)
LPH-101 -124LVS
1.2 (0.047)
※
2 60
200 (7.1)
※
2 170 (6.7)
-144LVS
1.4 (0.055)
※
2 80
200 (7.1)
※
2 180 (7.1)
0.10 (1.0 /14)
0.05
(0.5/7.1)
※
2 95
200 (7.1)
※
2 190 (7.5)
-164LVS
Suction
1.6 (0.063)
LV4
0.13 (1.3 /18)
0.07
(0.7/10)
120
240 (8)
200 (7.9)
Air
G
1/4
(
NPS1/4)
Fluid
G
1/4
(
NPS1/4)
295