Problem

Possible cause

Solution

The appliance does
not cool at all

Plug is not connected to
the mains socket properly

Connect the mains plug
properly

There is no voltage in the
mains socket (try to con-
nect another appliance
into it)

Call an electrician

The appliance is not
switched on

Switch on the appliance

Temperature Regulator is
not on

Check the Temperature
Regulator

Green indicator
flashing

Temperature sensor
problem

Call the service personnel

8.1 Closing the door

1.

Clean the door gaskets.

2.

If necessary, adjust the door. Refer
to "Installation".

3.

If necessary, replace the defective
door gaskets. Contact the Service
Center.

9. INSTALLATION

WARNING!
Read the "Safety Information"
carefully for your safety and cor-
rect operation of the appliance
before installing the appliance.

9.1 Positioning

This appliance can be installed in a dry,
well ventilated indoor (garage or cellar)
also, but for optimum performance in-
stall this appliance at a location where
the ambient temperature corresponds to

the climate class indicated on the rating
plate of the appliance:

Cli-
mate
class

Ambient temperature

SN

+10°C to + 32°C

N

+16°C to + 32°C

ST

+16°C to + 38°C

T

+16°C to + 43°C

9.2 Levelling

When placing the appliance ensure that
it stands level. This can be achieved by
two adjustable feet at the bottom in
front.