Operation – GEARENCH U118115H PETOL HYDRA-TORK User Manual
Page 15
15
Operation
Controls
The operating controls are shown on Figures 1 and 2 on page 16.
The disconnect switch is used to disconnect electrical power to the controls. When this
switch is on, the motor may be started.
The POWER ON switch will start the hydraulic pump motor. It contains an indicator light
to show that the motor is on. The POWER OFF switch is used to stop the motor.
The FILTER indicator light is used to monitor the hydraulic filter. If this light is on while a
cylinder is traveling the hydraulic filter element, located in the lower portion of the console,
is dirty and must be replaced. Use Schroeder MS-7 element or equal.
The TONG RATCHET and TONG ENGAGE buttons are used to control operation of the
main cylinder. Press the TONG ENGAGE button to apply torque. Press the TONG
RATCHET button to ratchet the tong back to the pull down position.
The pressure control knob is used to adjust the overall system pressure. Turn the knob
clockwise to increase pressure or counter-clockwise to decrease system pressure.
WARNING: Never operate the tong with a pressure higher than required to
perform the make up or break out operation. Operation at excessive pressure
may damage the downhole tool and/or injure personnel.
WARNING: Never operate the 115H tong or vise at a pressure greater than
1880 psi. Excessive pressure will damage the tong and vise and/or personnel.
The hydraulic pressure gauge is used to indicate the current system pressure in psi. A
conversion chart for equating the hydraulic pressure in psi to the torque output in ft-lb.
follows: