7.2.1 Air fi ltering
NOTICE
Insuffi cient maintenance on the air fi lter
The power of the machine lessens and damage may
occur to the machine..
Intake air fi lter:
The micro fi lter (Fig. 5/f
1
) must be cleaned by rinsing out
or purging or replaced more or less often depending
on how dirty the discharged medium is.
Remove the fi lter housing (Fig. 5/D) after undoing
the screws (Fig. 5/s
1
). Remove and clean the micro
fi lter.
Gas ballast valve fi lter:
The pumps work with a gas ballast valve (Fig. 4/U).
The inbuilt fi lter disc (Fig. 6/f
3
) and micro fi lter discs
(Fig. 6/f
4
) must be cleaned more or less often by
purging depending on how dirty the medium fl ow-
ing through is. By undoing the countersunk screw
(Fig. 6/g
1
) and removing the plastic cover (Fig. 6/h
1
)
the fi lter parts can be removed for cleaning.
Re-assemble in reverse order.