beautypg.com

Elmo Rietschle V-VTR 100/140 User Manual

Page 13

background image

13

www.gd-elmorietschle.com © Gardner Denver Schopfheim GmbH, Gardner Denver Deutschland GmbH

|

Bauj./Nr. 09

S1 3,00 / 3,60

kW

Typ VTR 100 (01)

150 mbar (abs.)

2849751

100 / 120 m³/h

EN 60034

1410 / 1700 min

-1

1027610116

3~

Mot.

Set up and operation

6

1

7

8

9

10

3

4

5

2

4.2 Description

The V-VTR model range has a connecting thread on the suction side and an exhaust silencer on the pres-
sure side. The aspirated air is cleaned by an inbuilt fi ne micro fi lter. The carbon dust caused by the scoring
of the blades can be separated by an integral fi lter if necessary. A fan between the compressor housing and
the motor provides intensive air cooling. The compressor housing is located in a sound cover.
The machines are driven by standard fl anged three-phase motors using a coupling.
A vacuum regulating valve (Fig. 2/C) is used to set the vacuum to the required values with an upper limit.

4.3

Areas of application

These dry running rotary vane vacuum pumps V-VTR 100 and V-VTR 140 are suitable for evacuating closed
systems and for a permanent vacuum in the intake pressure range 150 - 1000 mbar (abs.).

The pumping capacity with unrestricted suction is 100 and 140 m

3

/h at 50 Hz. Data sheet D 261 shows the

dependency of the pumping capacity on the intake pressure.

These dry running machines are suitable for conveying air with a relative humidity of 30 - 90%.

If the unit is switched on more frequently (at regular intervals of about 10 times an hour) or at
higher ambient temperatures and intake temperatures, the excess temperature limit of the motor
winding and the bearings may be exceeded.
Please contact the manufacturer should the unit be used under such conditions

If it is installed in the open air the unit must be protected from environmental infl uences, (e.g. by a
protective roof).

Fig. 3 Data plate

4.1.1 Data plate

1

Type/ Size (mechanical version)

2

Year of construction

3 Motor

design

4 Serial

number

5 Item

no

6

Final pressure (abs.)

7

Pumping capacity 50 Hz / 60 Hz

8 Speed

50

Hz / 60

Hz

9

Motor output 50 Hz / 60 Hz

10 Operating

mode