Malfunctions: Causes and elimination
Fault
Cause
Troubleshooting
Important
Final pressure (max.
overpressure) is not
reached
Machine or system leaking
Check the pipework and
screw connections for leaks
and to ensure that they are
fi rmly seated.
Section 7.2
Discs are worn or damaged
Replace discs
Section 7.2.2
Section 7.4
Driving power selection too
low
Use next largest motor output
Data sheet
D 361
Machine gets too hot
Ambient or intake temperature
is too high
Ensure it is being used prop-
erly
Section 2.3
Cooling air supply is ob-
structed
Check environmental condi-
tions
Section 5.1
Clean ventilation slots
Section 7.2
The blow out fi lter cartridge
(accessory) is dirty.
Clean or replace the fi lter
cartridges
Section 7.2.3
Section 7.4
The regulating valve is dirty so
that the permissible pressure
value is exceeded.
Clean or replace the regulat-
ing valve
Section 7.2
Section 7.4
The machine makes
a abnormal noise
The coupling rubbers are
worn
Replace coupling rubbers
Section 7.2.4
Section 7.4
The compressor housing is
worn (chatter marks)
Repair by manufacturer or
authorised workshop
Elmo Rietschle
Service
The regulating valve is vibrat-
ing
Replace the valve
Section 7.4
Discs are damaged
Replace discs
Section 7.2.2
Section 7.4
Please contact Elmo Rietschle Service for other malfunctions or those that cannot be eliminated.