Elmo Rietschle V-KTN 15/25/40 User Manual
Page 16
![background image](/manuals/316197/16/background.png)
16
|
www.gd-elmorietschle.com © Gardner Denver Schopfheim GmbH, Gardner Denver Deutschland GmbH
Installation
5.3 Connecting
pipes
a) Vacuum connection at (Fig. 2/A) and pressure
connection at (Fig. 2/B).
NOTICE
Material damage resulting from the forces and
torques of the pipes on the unit being too high.
screw pipes in by hand.
The machine output is reduced if the pipes are
too narrow and/or too long.
b) Check to ensure the intake line and pressure line
are connected correctly.
NOTICE
Length of the connection pipes
With connection pipes that have the same pipe
cross section as the machine connection and are
more than 3m long, a non-return valve especially
for the purpose must be installed in order to avoid
reverse operation when the machine has stopped
5.4
Control and relief valves
The required pressure and vacuum ranges can be
set with the pressure regulating valve (Fig. 2/D) and
the vacuum regulating valve (Fig. 2/C) as shown on
the symbol plate attached to the rotary knob.
NOTICE
Do not operate without the standard control
and relief valves.
If the permissible fi nal compression pressure is
exceeded (see data plate) the machine may be
damaged.