7.2.1 Air fi ltering
Fig. 5 Purging fi lter cartridge
1 Filter
cartridge
2
Compressed air
Fig. 4 Air fi ltering
D
Pressure regulating valve
G
Outlet grid
b Housing
cover
e, f Filter
cartridge
m
Knurled knob
s
Screw cap
NOTICE
Insuffi cient maintenance on the air fi lter
The power of the machine lessens and damage may
occur to the machine.
The fi lter cartridges for incoming air (Fig. 4/e) and
blowing air (Fig. 4/f
➝ accessory) must be cleaned
by blowing through from the inside out once a
month or more often depending on the level of con-
tamination. In spite of cleaning the filters their sepa-
ration efficiency will continue to deteriorate. There-
fore the fi lters should be replaced every six months.
Changing fi lters:
Unscrew the outlet grid (Fig. 4/G). Undo the screw
cap (Fig. 4/s) and the knurled knob (Fig. 4/m). Re-
move and clean or replace fi lter cartridges (e) and (f).
Reassemble in reverse order.
WARNING
Danger of injury when dealing with com-
pressed air.
When blowing through with compressed air, solid
particles may be carried along or powder dust swir-
ling around may cause injury to the eyes. Therefore,
when cleaning with compressed air always wear