beautypg.com

Liberty Pumps FL100-Series User Manual

Page 3

background image

©Copyright 2014 Liberty Pumps Inc. All rights reserved

3

MODEL SPECIFICATIONS

Model

HP

Volts

Full Load

Amps

Solids

Handling

Automatic or

Manual

Shut-off

Head

Factory Switch Setting

Turn-on

Turn-off

250*

1/3

115

5.2

1/2”

Manual*

22 ft.

*

*

251

1/3

115

5.2

1/2”

Automatic

22 ft.

11”

4-

1/2”

253

1/3

115

5.2

1/2”

Automatic

22 ft.

11”

4-

1/2”

257

1/3

115

5.2

1/2”

Automatic

22 ft.

7”

3-

1/2”

250HV*

1/3

230

2.6

1/2”

Manual*

22 ft.

*

*

251HV

1/3

230

2.6

1/2”

Automatic

22 ft.

11”

4-

1/2”

257HV

1/3

230

2.6

1/2”

Automatic

22 ft.

7”

3-

1/2”

280*

1/2

115

8.5

3/4”

Manual*

37 ft.

*

*

281

1/2

115

8.5

3/4”

Automatic

37 ft.

13”

7”

283

1/2

115

8.5

3/4”

Automatic

37 ft.

13”

7”

287

1/2

115

8.5

3/4”

Automatic

37 ft.

9-

1/2”

4”

280HV*

1/2

208-230

4.6

3/4”

Manual*

37 ft.

*

*

281HV

1/2

208-230

4.6

3/4”

Automatic

37 ft.

13”

7”

283HV

1/2

208-230

4.6

3/4”

Automatic

37 ft.

13”

7”

287HV

1/2

208-230

4.6

3/4”

Automatic

37 ft.

9-

1/2”

4”

290*

3/4

115

10.4

3/4”

Manual*

48 ft.

*

*

291

3/4

115

10.4

3/4”

Automatic

48 ft.

13”

7”

293

3/4

115

10.4

3/4”

Automatic

48 ft.

13”

7”

297

3/4

115

10.4

3/4”

Automatic

48 ft.

9-

1/2”

4”

290HV*

3/4

208-230

5.3

3/4”

Manual*

48 ft.

*

*

291HV

3/4

208-230

5.3

3/4”

Automatic

48 ft.

13”

7”

293HV

3/4

208-230

5.3

3/4”

Automatic

48 ft.

13”

7”

297HV

3/4

208-230

5.3

3/4”

Automatic

48 ft.

9-

1/2”

4”

FL31M*

1/3

115

10.5

3/4”

Manual*

19 ft.

*

*

FL31A

1/3

115

10.5

3/4”

Automatic

19 ft.

12”

5”

FL32M*

1/3

208-230

5.5

3/4”

Manual*

19 ft.

*

*

FL32A

1/3

208-230

5.5

3/4”

Automatic

19 ft.

12”

5”

FL51M*

1/2

115

12

3/4"

Manual*

55 ft.

*

*

FL51A

1/2

115

12

3/4"

Automatic

55 ft.

13

6”

FL52M*

1/2

208-230

6.5

3/4"

Manual*

55 ft.

*

*

FL52A

1/2

208-230

6.5

3/4"

Automatic

55 ft.

13

6”

FL62M*

6/10

208-230

8.2

3/4"

Manual*

65 ft.

*

*

FL62A

6/10

208-230

8.2

3/4"

Automatic

65 ft.

13

6”

FL63M*

6/10

208-230 3PH

5.6

3/4"

Manual*

65 ft.

*

*

FL64M*

6/10

440-480 3PH

2.8

3/4"

Manual*

65 ft.

*

*

FL72M*

3/4

208-230

10.5

3/4"

Manual*

77 ft.

*

*

FL72A

3/4

208-230

10.5

3/4"

Automatic

77 ft.

13

6”

FL73M*

3/4

208-230 3PH

7.5

3/4"

Manual*

77 ft.

*

*

FL74M*

3/4

440-480 3PH

3.5

3/4"

Manual*

77 ft.

*

*

FL102M*

1

208-230

12

3/4”

Manual*

90 ft.

*

*

FL102A

1

208-230

12

3/4”

Automatic

90 ft.

15”

8”

FL103M*

1

208-230 3PH

9

3/4”

Manual*

90 ft.

*

*

FL104M*

1

440-480 3PH

4.5

3/4”

Manual*

90 ft.

*

*

FL105M*

1

575 3PH

3.3

3/4”

Manual*

90 ft.

*

*

FL152M*

1-1/2

208-230

15

3/4”

Manual*

110 ft.

*

*

FL152A

1-1/2

208-230

15

3/4”

Automatic

110 ft.

15”

8”

FL153M*

1-1/2

208-230 3PH

10.6

3/4”

Manual*

110 ft.

*

*

FL154M*

1-1/2

440-480 3PH

5.3

3/4”

Manual*

110 ft.

*

*

FL155M*

1-1/2

575 3PH

4.9

3/4”

Manual*

110 ft.

*

*

FL202M*

2

208-230

15

3/4”

Manual*

130 ft.

*

*

FL202A

2

208-230

15

3/4”

Automatic

130 ft.

15”

8”

FL203M*

2

208-230 3PH

10.6

3/4”

Manual*

130 ft.

*

*

FL204M*

2

440-480 3PH

5.3

3/4”

Manual*

130 ft.

*

*

FL205M*

2

575 3PH

4.9

3/4”

Manual*

130 ft.

*

*

Note: Manual models (“M” suffix) and 3 phase models, as designated above, require a separate approved pump control device or panel for automatic
operation. Operation of these models will be according to the control selected. Make sure the electrical specifications of the control selected properly
match the electrical specifications of the pump. 3 phase models require overload elements selected or adjusted in accordance with the control or panel
instructions.



WARNING:
Always use a replacement power cord assembly of the same length and type as originally installed on the Liberty product. Using a
cord of improper gauge or length may lead to exceeding the electrical rating of the cord and could result in death, injury, fire or other
significant failure.

This manual is related to the following products: