OPERATION

burns and injuries. If overheating of the
pump occurs:

1. Stop the pump immediately.
2. Ventilate the area.
3. Allow the pump to completely cool.
4. Check the temperature before ser­

vicing.

5. Vent the pump slowly and cau­

tiously

6. Refer to instructions in this manual

before restarting the pump.

Impeller Rotation

Check impeller rotation as follows before operation
to ensure that the impeller is rotating in the correct
direction.

While checking impeller rotation, secure
the pump to prevent the power cable from
coiling.

Suspend the pump from the lifting device fitted on
the pump. Apply power briefly and note the direc­
tion of pump kickback. As viewed from the top, the
pump should kick in a counterclockwise direc­
tion; this will indicate that impeller rotation is cor­
rect.

If the pump kicks in a clockwise direction, impeller
rotation is incorrect. If the pump is powered by a
three‐phase motor, have a qualified electrician in­
terchange the control box connections of any two
pump motor power leads. Re‐check pump kick­
back; it should now be in a counterclockwise direc­
tion.

If rotation is incorrect on a single‐phase motor, con­
tact the factory before installing the pump.

The electrical power used to operate
this pump is high enough to cause inju­

ry or death. Make certain that incoming
power is off and locked out before inter­
changing motor leads.

DIRECTION OF

KICKBACK

AT STARTUP

Figure C-1. Checking Pump Rotation

STARTING, STOPPING, AND
OPERATIONAL CHECKS

Starting

Do not attempt to operate the pump until
impeller rotation has been checked; im­
proper rotation will affect pump perform­
ance and may damage the pump.

Follow the instructions accompanying the control
box, start the pump, and run any recommended
checks.

Do not start the pump more than 10 times
per hour. If the pump motor does not cool