1
Legend
1) 4-Way Open-Center Directional Valve
(Must be operated in forward direction
only or use check valve (4) to prevent
reversing.)
2) Valved Quick Disconnect Coupling
3) Hydraulic Motor Driven
Submersible Pump
4) Check Valve (Recommended)
5) Flow Control (Recommended if hydraulic
flow is greater than flow required by
submersible pump.)
2
5
2
3
2
4
2
Submersible Pump
Do not use closed-center valves. Return
flow from the hydraulic motor must be
allowed to return directly to the oil res-
ervoir to enable the pump impeller to
gradually slow to a stop. Closed-center
valves will block this flow, causing dam-
age to the hydraulic motor and/or the
pump seal.
Figure 1. Typical Hydraulic Schematic for Customer-Supplied Power Source