beautypg.com

Gorman-Rupp Pumps PA4A60C-F3L 1303165 and up User Manual

Page 46

background image

PA SERIES

OM−05765

MAINTENANCE & REPAIR

PAGE E − 24

A new seal assembly should be installed
any time the old seal is removed from the
pump. Wear patterns on the finished faces

cannot be realigned during reassembly.
Reusing an old seal could result in prema-
ture failure.

To ease installation of the seal, lubricate the shaft
sleeve O-ring and the external stationary seat O-
ring with a very small amount of light lubricating oil.
See Figure 12 for seal part identification.

SEAL PLATE

O-RINGS

IMPELLER

SHAFT

STATIONARY

SEAT

STATIONARY

ELEMENT

ROTATING

ELEMENT

DRIVE BAND

BELLOWS

IMPELLER

SHIMS

IMPELLER

SPRING

RETAINER

INTEGRAL

SHAFT

SLEEVE

SLEEVE

O-RING

SPRING

CENTERING

WASHER

SHEAR

RING

(SHEARED)

Figure 12. 46513−151 Cartridge Seal Assembly

This seal is not designed for operation at
temperatures above 160

_

F (71

_

C). Do not

use at higher operating temperatures.

If the seal plate was removed, install the seal plate
gasket (5). Position the seal plate over the shaft
and secure it to the bearing housing with the hard-
ware (7 and 8).

To prevent damaging the shaft sleeve O-ring (26)
on the shaft threads, stretch the O-ring over a piece
of tubing. The I.D. of the tubing must be slightly
larger than the O.D. of the shaft. To ease installation
the tubing wall should be as thin as possible. The
length should be long enough to cover the threads

on the end of the shaft. Slide the tube over the shaft
threads, then slide the O-ring off the tube and onto
the shaft. Remove the tube, and continue to slide
the O-ring down the shaft until it seats against the
shaft shoulder.

When installing a new cartridge seal assembly,
remove the seal from the container, and remove
the mylar storage tabs from between the seal
faces.

New cartridge seal assemblies may be
equipped with mylar storage tabs between
the seal faces. These storage tabs must be
removed before installing the seal.