beautypg.com

Gorman-Rupp Pumps PA6C60-4045H 1416490 thru 1485125 User Manual

Page 43

background image

OM−06081

PA SERIES

MAINTENANCE & REPAIR

PAGE E − 23

Impeller Installation And Adjustment

(Figure 5)

Inspect the impeller (1) and replace it if cracked or
badly worn.

The shaft and impeller threads must be
completely clean before reinstalling the im-
peller. Even the slightest amount of dirt on
the threads can cause the impeller to seize
to the shaft, making future removal difficult
or impossible without damage to the im-
peller or shaft.

Install the same thickness of impeller adjusting
shims (31) as previously removed and screw the
impeller assembly onto the shaft until tight.

NOTE

At the slightest sign of binding, immediately back
the impeller off, and check the threads for dirt. Do
not try to force the impeller onto the shaft.

A clearance of .025 to .040 inch (0,64 to 1,02 mm)
between the impeller and the seal plate is neces-
sary for maximum pump efficiency. Measure this
clearance, and add or remove impeller adjusting
shims as required.

Secure the impeller to the shaft with the impeller
washer and capscrew (22 and 23).

Pump Casing Installation

(Figure 4)

Lubricate the rotating assembly O-rings (31 and
32) with a light coating of grease. Use a suitable
hoist and sling to slide the pump casing (1) over the
rotating assembly.

Install two shims (11) at each mounting location
and secure the casing to the rotating assembly (2)
with the hardware (9 and 10).

Wear Plate And Back Cover Plate Installation
And Adjustment

(Figures 4 and 11)

If the wear plate (5) was removed for replacement,
carefully center it on the back cover plate assembly
(16) and secure it with the hardware (3 and 4).

Lubricate the O-rings (6 and 15) with light grease
and install them in the grooves in the wear plate
and back cover.

Clearance between the impeller and wear plate is
adjusted using the four back cover nuts (20) and
locking collars (17). There are 18 detents on the
I.D. of each locking collar. Indexing the collars one
detent on the adjusting screws represents approxi-
mately .005 inch (0,13 mm) of wear plate clear-
ance. The recommended clearance between the
wear plate and the impeller is .010 to .020 inch
(0,25 to 0,50 mm).

USE TWO
OPPOSING
BACK COVER
NUTS TO PRESS
BACK COVER
INTO PUMP
CASING

USE TWO REMAINING
ADJUSTING SCREWS AND
LOCKING COLLARS TO SET
FACE CLEARANCE

TURN INDEX COLLARS
3 DETENTS COUNTER-
CLOCKWISE, THEN
TURN CLOCKWISE UN-
TIL SCREW HOLES
ALIGN

Figure 11. Installing and Adjusting Back Cover

Screw the four adjusting screws (18) into the
tapped holes in the back cover plate until they are
just flush with the machined surface on the back
side of the cover plate.

Align the back cover plate over the studs (19) and
slide it into the pump casing. Use two back cover
nuts (20) on diagonally opposing studs to press