beautypg.com

Gorman-Rupp Pumps PAH4C60C-B 1503565 and up User Manual

Page 10

background image

OM-06479

PAH SERIES

PAGE B - 2

INSTALLATION

Mounting

Locate the pump in an accessible place as close as
practical to the liquid being pumped. Level mount­
ing is essential for proper operation.

The pump may have to be supported or shimmed
to provide for level operation or to eliminate vibra­
tion.

SUCTION AND DISCHARGE PIPING

Pump performance is adversely effected by in­
creased suction lift, discharge elevation, and fric­
tion losses. See the performance curve and oper­
ating range shown on Page E‐1 to be sure your
overall application allows pump to operate within
the safe operation range.

Materials

Either pipe or hose maybe used for suction and
discharge lines; however, the materials must be
compatible with the liquid being pumped. If hose is
used in suction lines, it must be the rigid‐wall, rein­
forced type to prevent collapse under suction. Us­
ing piping couplings in suction lines is not recom­
mended.

Line Configuration

Keep suction and discharge lines as straight as
possible to minimize friction losses. Make mini­
mum use of elbows and fittings, which substan­
tially increase friction loss. If elbows are necessary,
use the long‐radius type to minimize friction loss.

Connections to Pump

Before tightening a connecting flange, align it ex­
actly with the pump port. Never pull a pipe line into
place by tightening the flange bolts and/or cou­
plings.

Lines near the pump must be independently sup­
ported to avoid strain on the pump which could
cause excessive vibration, decreased bearing life,
and increased shaft and seal wear. If hose‐type
lines are used, they should have adequate support

to secure them when filled with liquid and under
pressure.

Gauges

Most pumps are drilled and tapped for installing
discharge pressure and vacuum suction gauges. If
these gauges are desired for pumps that are not
tapped, drill and tap the suction and discharge
lines not less than 18 inches (457,2 mm) from the
suction and discharge ports and install the lines.
Installation closer to the pump may result in erratic
readings.

SUCTION LINES

To avoid air pockets which could affect pump prim­
ing, the suction line must be as short and direct as
possible. When operation involves a suction lift, the
line must always slope upward to the pump from
the source of the liquid being pumped; if the line
slopes down to the pump at any point along the
suction run, air pockets will be created.

Fittings

Suction lines should be the same size as the pump
inlet. If reducers are used in suction lines, they
should be the eccentric type, and should be in­
stalled with the flat part of the reducers uppermost
to avoid creating air pockets. Valves are not nor­
mally used in suction lines, but if a valve is used,
install it with the stem horizontal to avoid air pock­
ets.

Strainers

If a strainer is furnished with the pump, be certain
to use it; any spherical solids which pass through a
strainer furnished with the pump will also pass
through the pump itself.

If a strainer is not furnished with the pump, but is
installed by the pump user, make certain that the
total area of the openings in the strainer is at least
three or four times the cross section of the suction
line, and that the openings will not permit passage
of solids larger than the solids handling capability
of the pump.

This pump is designed to handle up to 1/2‐inch
(12,7 mm) diameter spherical solids.