Gorman-Rupp Pumps 3D-E1.5 1P 883504 and up User Manual
Page 32
D SERIES
OM-03604
MAINTENANCE & REPAIR
PAGE E - 16
Use a grease gun to apply No. 2 lithium base
grease to the upper lubrication fitting until grease
escapes from the eccentric cap. Lubricate the low
er fitting until grease escapes from the top of the
upper diaphragm plate inside the spring.
Gearbox
(Figure 4)
The gearbox was fully lubricated when shipped
from the factory. Change the oil in a new gearbox at
operating temperature after 100 hours of operation
or four weeks, whichever comes first. To drain the
oil, remove the oil cup (29) and position the pump
and gearbox on its side. After draining, reinstall the
oil cup and flush the case thoroughly with a light oil.
Remove the oil cup and drain the flushing oil. Rein
stall the oil cup.
To lubricate the gearbox, add SAE No. 30 non‐de
tergent oil through the oil cup (29) until the oil level
stabilizes at the middle of the oil cup. Check the oil
regularly and maintain it at this level.
Monitor the condition of the bearing lubri
cant regularly for evidence of rust or mois
ture condensation. This is especially im
portant in areas where variable hot and
cold temperatures are common.