beautypg.com

Gorman-Rupp Pumps VGH1 1/4D31-B 1364934 thru 1211819 User Manual

Page 20

background image

OM−06114

VGH SERIES

TROUBLESHOOTING

PAGE D − 2

Table D-1 Troubleshooting Chart (Continued)

TROUBLE

POSSIBLE CAUSE

PROBABLE REMEDY

PUMP STOPS OR FAILS
TO DELIVER RATED
FLOW OR PRESSURE
(cont.)

Impeller or other wearing parts worn
or damaged.

Leaking or worn seal or pump gas-
ket.

Impeller clogged.

Pump running backwards (electric
motor driven models).

Suction lift or discharge head too
high.

Liquid solution too thick.

Replace worn or damaged parts.
Check that impeller is properly cen-
tered and rotates freely.

Check pump vacuum. Replace leak-
ing or worn seal or gasket.

Free impeller of debris.

Check direction of rotation. Correct
3-phase wiring by interchanging any
two motor leads at control box. (See
Pump Rotation in the Installation
and Operations Manual.)

Check piping installation and install
bypass line if needed. See INSTAL-
LATION in the Installation and Op-
erations manual.

Dilute if possible.

PUMP REQUIRES TOO
MUCH POWER

Pump speed too high.

Discharge head too low.

Liquid solution too thick.

Impeller jammed due to debris or in-
sufficient clearance.

Check governor setting (engine driv-
en models).

Adjust discharge valve.

Dilute if possible.

Disassemble pump and check impel-
ler.

PUMP CLOGS
FREQUENTLY

Discharge flow too slow.

Suction check valve or foot valve
clogged or binding.

Open discharge valve filly to in-
crease flow rate, and run power
source at maximum governed
speed.

Clean valve.

EXCESSIVE NOISE

Cavitation in pump.

Pumping entrained air.

Pump or drive not securely
mounted.

Impeller clogged or damaged.

Reduce suction lift and/or friction
losses in suction line. Record vacu-
um and pressure gauge readings
and consult local representative or
factory.

Locate and eliminate source of air
bubble.

Secure mounting hardware.

Clean out debris; replace damaged
parts.