beautypg.com

Gorman-Rupp Pumps VGH3C31-B 1379872 thru 1208728 User Manual

Page 31

background image

OM−06124

VGH SERIES

MAINTENANCE & REPAIR

PAGE E − 9

sleeve is just flush with the shaft shoulder. Secure
the sleeve to the shaft with the setscrew (54).

Install a new gasket (38) in the step on the front of
the seal flange.

Align the studs (9 and 36) with the holes in the
bearing housing and seal flange and slide the seal
plate (39) over the shaft until the step on the O.D. of
the seal plate is fully seated in the bearing housing.
Make sure the coupling (5) in the seal flange is
properly aligned for installation of the vent line (8).
Secure the seal plate to the bearing housing with
the nuts (10).

Secure the seal flange to the seal plate with the
nuts (35).

Impeller and Pump Casing Installation

Inspect the impeller, and replace it if cracked or
badly worn. Install the impeller key (51) in the shaft
keyway. Align the impeller keyway with the key and
slide the impeller onto the shaft until fully seated.

NOTE

After the impeller has been properly positioned,
check for free rotation. Correct any scraping/bind-
ing before further reassembly.

When the impeller is properly positioned, install the
impeller washer and nut (45 and 46). Secure the
impeller nut with the safety plate (50) and screw
(47).

Install the casing gasket (41). Slide the pump cas-
ing (1) over the impeller and secure it to the seal
plate with the nuts (7).

Reinstall the bypass pipe (8).

NOTE

After the pump casing has been installed, check the
impeller for free rotation and correct any scraping
or binding.

Final Pump Assembly

Remove the wood block supporting the bearing
housing. Secure the pump and bearing housing

foot to the base with the previously removed hard-
ware. Be sure to reinstall any leveling shims used
under the pump mounting feet.

Be sure the pump and power source are securely
mounted to the base. Reinstall the shaft key (55)
and install the power source coupling.

Install the suction and discharge lines. Make cer-
tain that all piping connections are tight, properly
supported and secure. Open all the valves in the
suction and discharge lines.

Be sure the pump and power source have been
properly lubricated, see LUBRICATION.

Fill the pump casing with clean liquid. Refer to OP-
ERATION, Section C, before putting the pump
back into service.

LUBRICATION

Seal Assembly

The seal assembly is lubricated by the medium be-
ing pumped and no additional lubrication is re-
quired.

Bearings

The bearing housing was not lubricated when
shipped from the factory. To lubricate the bearing
cavity, fill the constant level oiler as shown in Figure
3, then close the oiler and allow the oil to drain into
the bearing cavity. Repeat this procedure until oil
no longer drains from the constant level oiler.

FILL ONLY

THROUGH

CONSTANT

LEVEL OILER

DO NOT FILL

THROUGH

VENT PLUG

Figure 3. Lubricating Bearing Cavity