Table D-1 Troubleshooting Chart
TROUBLE
POSSIBLE CAUSE
PROBABLE REMEDY
PUMP FAILS TO PRIME
Auxiliary priming device faulty or im-
properly installed.
Discharge check valve open.
Air leak in suction line.
Lining of suction hose collapsed.
Leaking or worn seal or pump gas-
ket.
Strainer clogged.
Repair priming device or check
installation.
Check position of handle; close
valve.
Correct leak.
Replace suction hose.
Check pump vacuum. Replace leak-
ing or worn seal or gasket.
Check strainer and clean if neces-
sary.
PUMP STOPS OR FAILS
TO DELIVER RATED
FLOW OR PRESSURE
Air leak in suction line.
Lining of suction hose collapsed.
Suction intake not submerged at
proper level or sump too small.
Strainer clogged.
Correct leak.
Replace suction hose.
Check installation and correct sub-
mergence as needed.
Check strainer and clean if neces-
sary.