beautypg.com

Gorman-Rupp Pumps VGH8D31-B 1379872 thru 1208738 User Manual

Page 13

background image

OM−06132

VGH SERIES

PAGE B − 6

INSTALLATION

MISALIGNED:

SHAFTS

NOT PARALLEL

MISALIGNED:

SHAFTS

NOT IN LINE

ALIGNED: SHAFTS

PARALLEL AND

SHEAVES IN LINE

Figure 3C. Alignment of V-Belt Driven Pumps

Tighten the belts in accordance with the belt manu-
facturer’s instructions. If the belts are too loose,
they will slip; if the belts are too tight, there will be
excessive power loss and possible bearing failure.
Select pulleys that will match the proper speed ra-
tio; overspeeding the pump may damage both
pump and power source.

Do not operate the pump without the
guard in place over the rotating parts

.

exposed rotating parts can catch cloth-
ing, fingers, or tools, causing severe in-
jury to personnel.

ELECTRICAL CONNECTIONS

If the pump is driven by an electric motor, check
that the electrical service available matches the
motor requirements stamped on the motor name-
plate before connecting a motor to the incoming
power. Check that the motor speed meets pump
specifications.

If rotation is incorrect on a three-phase motor, have
a qualified electrician interchange any two of the
three phase wires to change direction. If rotation is
incorrect on a single-phase motor, consult the lit-
erature supplied with the motor for specific instruc-
tions.

The electrical power used to operate the
pump is high enough to cause injury or
death. Obtain the services of a qualified
electrician to make all electrical con-
nections.

If the pump is powered by an electric
motor, do not operate a non-explosion
proof motor in an explosive atmo-
sphere. An explosion, which may cause
severe personal injury or death, could
result. Install, connect and operate the
motor in accordance with the National
Electric Code and all local codes. If
there is a conflict between the instruc-
tions in the manual accompanying the
unit and the National Electric Code or
applicable local code, the National or
Local code shall take precedence. All
electrical equipment supplied with the
pump conforms to applicable federal
regulations and national codes in effect
on the date of manufacture.

GROUNDING

If the pump has been approved to pump volatile or
flammable liquids, the unit must be grounded by
attaching the ground wire assembly to a ground
rod in order to eliminate electrostatic build-up by
the liquid being pumped. Install the ground rod in
accordance with the National Electrical Codes and
all local codes. Be sure the fastening device makes
a tight electrical connection with the rod and the
pump.

Inspect and test the ground wire assembly
for conductivity. replace broken or frayed
wire before resuming operation.