the retaining ring on the outboard bearing seats
against the bearing housing. Remove the lip seal
sleeve.
When installing the shaft and bearings into
the bearing bore, push against the outer
race. Never hit the balls or ball cage.
Position the outboard oil seal (22) on the lubricated
shaft with the lip positioned as shown in Figure 2.
Press the oil seal into the bearing housing until the
face of the seal is just flush with the machined sur
face on the bearing housing.
Press the outboard oil seal (12) into the bearing
cap (15) with the lip positioned as shown in Figure
2. Replace the bearing cap O‐ring (19), and secure
the bearing cap with the hardware (13 and 14). Be
careful not to damage the oil seal lip on the shaft
keyway.
Lubricate the bearing housing as indicated in LU
BRICATION.
Seal Installation
(Figures 2 and 5)
Most cleaning solvents are toxic and
flammable. Use them only in a well ven
tilated area free from excessive heat,
sparks, and flame. Read and follow all
precautions printed on solvent contain
ers.
Clean the seal cavity and shaft with a cloth soaked
in fresh cleaning solvent. Inspect the stationary
seat bore in the seal plate for dirt, nicks and burrs,
and remove any that exist. The stationary seat bore
must be completely clean before installing the
seal.
A new seal assembly should be installed
any time the old seal is removed from the
pump. Wear patterns on the finished faces
cannot be realigned during reassembly.
Reusing an old seal could result in prema
ture failure.
The seal is not normally reused because wear pat
terns on the finished faces cannot be realigned
during reassembly. This could result in premature
failure. If necessary to reuse an old seal in an emer
gency, carefully wash all metallic parts in fresh
cleaning solvent and allow to dry thoroughly.
Inspect the seal components for wear, scoring,
grooves, and other damage that might cause leak
age. Clean and polish the shaft sleeve, or replace it
if there are nicks or cuts on either end. If any com
ponents are worn, replace the complete seal;
never mix old and new seal parts.
If a replacement seal is being used, remove it from
the container and inspect the precision finished
faces to ensure that they are free of any foreign
matter.
To ease installation of the seal, lubricate the shaft
sleeve O‐ring and the external stationary seat O‐
ring with a very small amount of light lubricating oil.
See Figure 5 for seal part identification.