Gorman-Rupp Pumps T6B61S-B /F,/FM User Manual
Page 30
OM-05605
SUPER T SERIES
MAINTENANCE & REPAIR
PAGE E - 8
TEE
APPROX. 6 IN.
(152 MM) LONG
APPROX. 14 IN.
(356 MM) LONG
Figure 4. Rotating Assembly Tool
To install the tool, remove the vented plug (6, Figure
2) from the bearing housing, and screw the longest
length of pipe into the vent hole until fully engaged.
Install the tee, and screw the handles into the tee.
Use caution when lifting the rotating assembly to
avoid injury to personnel or damage to the assem
bly.
Remove the bearing housing O‐ring (8).
Impeller Removal
(Figure 2)
With the rotating assembly removed from the
pump casing, unscrew the impeller from the shaft.
Use caution when unscrewing the impeller; ten
sion on the shaft seal spring will be released as the
impeller is removed. Inspect the impeller and re
place if cracked or badly worn.
Remove the impeller adjusting shims (28); tie and
tag the shims, or measure and record their thick
ness for ease of reassembly.
Seal Removal
(Figure 2)
Remove the seal spring. Apply oil to the shaft and
work it up under the bellows. Use a pair of stiff wires
with hooked ends to remove the rotating portion of
the seal off the shaft.
Use a pair of stiff wires with hooked ends to remove
the stationary portion of the seal. An alternate
method of removing the stationary portion of the
seal is to remove the hardware (20 and 21) and
separate the seal plate (22) and gasket (3) from the
bearing housing (5). Position the seal plate on a flat
surface with the impeller side down. Use a wooden
dowel or other suitable tool to press on the back
side of the stationary seal until the seat, O‐rings
and stationary element can be removed.
If no further disassembly is required, refer to Seal
Installation.
Shaft and Bearing Removal and Disassembly
(Figure 2)
When the pump is properly operated and main
tained, the bearing housing should not require dis
assembly. Disassemble the shaft and bearings
only when there is evidence of wear or damage.
Shaft and bearing disassembly in the field
is not recommended. These operations
should be performed only in a properly‐
equipped shop by qualified personnel.
Remove the bearing housing drain plug (24) and
drain the lubricant. Clean and reinstall the drain
plug.
Disengage the hardware (15 and 16) and slide the
bearing cap (10) and oil seal (13) off the shaft. Re
move the bearing cap gasket (17) and press the oil
seal from the bearing cap.
Place a block of wood against the impeller end of
the shaft and tap the shaft (12) and assembled
bearings (4 and 9) from the bearing housing.
After removing the shaft and bearings, clean and
inspect the bearings in place as follows.
To prevent damage during removal from
the shaft, it is recommended that bearings
be cleaned and inspected in place. It is
strongly recommended that the bearings