Gorman-Rupp Pumps T6A61S-B /F,/FM User Manual
Page 33
OM-05268
SUPER T SERIES
MAINTENANCE & REPAIR
PAGE E - 11
faces to ensure that they are free of any foreign
matter.
To ease installation of the seal, lubricate the shaft
and O‐rings with a very small amount of light lubri
cating oil. See Figure 5 for seal part identification.
SEAL PLATE
O‐RINGS
IMPELLER
STATIONARY
STATIONARY
ROTATING
DRIVE BAND
BELLOWS
IMPELLER SHIMS
IMPELLER
SPRING
RETAINER
ELEMENT
ELEMENT
SEAT
SHAFT
Figure 5. 46512-192 Seal Assembly
This seal is not designed for operation at
temperatures above 160
_
F (71
_
C). Do not
use at higher operating temperatures.
Lubricate the stationary seat O‐ring with water or
light oil, and press the stationary subassembly into
the front of the seal plate (4) until it seats squarely
against the bore shoulder.
Install the seal plate gasket (5). Position the seal
plate and stationary seat over the shaft and secure
it to the bearing housing (9) with the hardware (7
and 8). Be careful not to damage the stationary
element on the shaft threads.
NOTE
It is recommended that a tapered sleeve be in
stalled over the threads of the impeller shaft to ease
installation of the rotating seal components.
Lubricate the shaft with a small amount of light oil
and slide the rotating subassembly (consisting of
the rotating element, bellows and retainer) onto the
shaft. Apply firm, steady pressure on the seal re
tainer until it slides onto the shaft and the seal faces
contact.
Install the seal spring. Lubricate the seal as indi
cated in LUBRICATION after the impeller is in
stalled.