Gorman-Rupp Pumps T4A60S-B /F,/FM,/WW User Manual
Page 30
OM-05143
SUPER T SERIES
MAINTENANCE & REPAIR
PAGE E - 7
Inspect the wear plate, and replace it if badly
scored or worn. To remove the wear plate, disen
gage the hardware (15 and 16).
Inspect the back cover O‐rings (14 and 18) and re
place it if damaged or worn.
Suction Check Valve Removal
(Figure 1)
If the check valve assembly (39) is to be serviced,
remove the check valve pin (40), reach through the
back cover opening and pull the complete assem
bly from the suction flange (35).
NOTE
Further disassembly of the check valve is not re
quired since it must be replaced as a complete unit.
Individual parts are not sold separately.
Rotating Assembly Removal
(Figure 2)
The rotating assembly may be serviced without
disconnecting the suction or discharge piping;
however, the power source must be removed to
provide clearance.
The impeller (1) should be loosened while the rotat
ing assembly is still secured to the pump casing.
Before loosening the impeller, remove the seal cav
ity drain plug (27) and drain the seal lubricant. This
will prevent the oil in the seal cavity from escaping
when the impeller is loosened. Clean and reinstall
the seal cavity drain plug.
Immobilize the impeller by wedging a block wood
between the vanes and the pump casing, and re
move the impeller capscrew and washer (22 and
23).
Install the shaft key (17). Install a lathe dog on the
drive end of the shaft (18) with the “V” notch posi
tioned over the shaft key.
With the impeller rotation still blocked, see Figure 3
and use a long piece of heavy bar stock to pry
against the arm of the lathe dog in a counterclock
wise direction (when facing the drive end of the
shaft). Use caution not to damage the shaft or key
way. When the impeller breaks loose, remove the
lathe dog, key and wood block.
NOTE
Do not remove the impeller until the rotating assem
bly has been removed from the pump casing.
Turn
Counterclockwise
Lathe Dog Arm
“V” Notch
Shaft Key
Impeller Shaft
Lathe Dog
Setscrew
Heavy
Bar Stock
Figure 3. Loosening Impeller
(Figure 1)
Remove the hardware (9 and 10) securing the ro
tating assembly to the pump casing. Separate the
rotating assembly by pulling straight away from the
pump casing. Tie and tag the rotating assembly
shims (11) for ease of reassembly.
NOTE
An optional disassembly tool is available from the
factory. If the tool is used, follow the instructions
packed with it. A similar tool may be assembled us
ing 1/2‐inch pipe (schedule 80 steel or malleable
iron) and a standard tee (see Figure 4). All threads
are 1/2‐inch NPT. Do not pre‐assemble the tool.