Gorman-Rupp Pumps 06B3-B 806819 and up User Manual
Page 26
0 SERIES
OM-01224
MAINTENANCE & REPAIR
PAGE E - 6
Place a block of wood against the impeller end of
the shaft (22) and tap the shaft and assembled
bearings (24 and 32) from the bearing housing.
After removing the shaft and bearings, clean and
inspect the bearings in place as follows.
To prevent damage during removal from
the shaft, it is recommended that bearings
be cleaned and inspected in place. It is
strongly recommended that the bearings
be replaced any time the shaft and bear
ings are removed.
Clean the bearing housing, shaft and all compo
nent parts (except the bearings) with a soft cloth
soaked in cleaning solvent. Inspect the parts for
wear or damage and replace as necessary.
Most cleaning solvents are toxic and
flammable. Use them only in a well ven
tilated area free from excessive heat,
sparks, and flame. Read and follow all
precautions printed on solvent contain
ers.
Clean the bearings thoroughly in fresh cleaning
solvent. Dry the bearings with filtered compressed
air and coat with light oil.
Bearings must be kept free of all dirt and
foreign material. Failure to do so will great
ly shorten bearing life. Do not spin dry
bearings. This may scratch the balls or
races and cause premature bearing fail
ure.
Rotate the bearings by hand to check for rough
ness or binding and inspect the bearing balls. If ro
tation is rough or the bearing balls are discolored,
replace the bearings.
The bearing tolerances provide a tight press fit
onto the shaft and a snug slip fit into the pedestal.
Replace the bearings, shaft, or pedestal if the
proper bearing fit is not achieved.
If bearing replacement is required, use a suitable
bearing puller to remove the bearings from the
shaft.
Shaft and Bearing Reassembly and
Installation
Clean the pedestal, shaft and all component parts
(except the bearings) with a soft cloth soaked in
cleaning solvent. Inspect the parts for wear or dam
age as necessary.
Most cleaning solvents are toxic and
flammable. Use them only in a well ven
tilated area free from excessive heat,
sparks, and flame. Read and follow all
precautions printed on solvent contain
ers.
Inspect the shaft for distortion, nicks or scratches,
or for thread damage on the impeller end. Dress
small nicks and burrs with a fine file or emery cloth.
Replace the shaft if defective.
Position the oil seal (15) in the bearing cap (13) with
the lip positioned as shown in Figure 1. Press the
oil seal into the bearing cap until the face is just
flush with the exterior surface of the bearing cap.
Secure bearing cap gasket (14) and bearing cap
to the pedestal with hardware (33).
To prevent damage during removal from
the shaft, it is recommended that bearings
be cleaned and inspected in place. It is
strongly recommended that the bearings
be replaced any time the shaft and bear
ings are removed.
The bearings may be heated to ease installation.
An induction heater, hot oil bath, electric oven, or
hot plate may be used to heat the bearings. Bear